Display System Environmental Sensors (CHRP)

This Service Aid displays the environmental sensors implemented on a CHRP system. The information displayed is the sensor name, physical location code, literal value of the sensor status, and the literal value of the sensor reading.

Note:

Runs on CHRP systems units only.



The sensor status can be any one of the following:

Normal
The sensor reading is within the normal operating range.

Critical High
The sensor reading indicates a serious problem with the device. Run diagnostics on sysplanar0 to determine what repair action is needed.

Critical Low
The sensor reading indicates a serious problem with the device. Run diagnostics on sysplanar0 to determine what repair action is needed.

Warning High
The sensor reading indicates a problem with the device. This could become a critical problem if action is not taken. Run diagnostics on sysplanar0 to determine what repair action is needed.

Warning Low
The sensor reading indicates a problem with the device. This could become a critical problem if action is not taken. Run diagnostics on sysplanar0 to determine what repair action is needed.

Hardware Error
The sensor could not be read because of a hardware error. Run diagnostics on sysplanar0 in problem determination mode to determine what repair action is needed.

Hardware Busy
The system has repeatedly returned a busy indication, and a reading is not available. Try the Service Aid again. If the problem continues, run diagnostics, on sysplanar0 in problem determination mode to determine what repair action is needed.



This Service Aid can also be run as a command. The command can be used to list the sensors and their values in a text format, list the sensors and their values in numerical format, or a specific sensor can be queried to return either the sensor status or sensor value.



The command can be run by entering one of the following:

/usr/lpp/diagnostics/bin/uesensor -l | -a

/usr/lpp/diagnostics/bin/uesensor -t token -i index [-v]

Flags

-l
List the sensors and their values in a text format.

-a
List the sensors and their values in a numerical format. For each sensor, the following numerical values are displayed as:


-t token
Specifies the sensor token to query.

-i index
Specifies the sensor index to query.

-v
Indicates to return the sensor measured value. The sensor status is returned by default.



Examples

Display a list of the environmental sensors:
/usr/lpp/diagnostics/bin/uesensor -l

Sensor Token = Fan Speed
Status = Normal
Value = 2436 RPM
Location Code = F1


Sensor Token = Power Supply
Status = Normal
Value = Present and operational Location Code = V1

Sensor Token = Power Supply
*Status = Critical low
Value = Present and not operational
Location Code = V2

Display a list of the environmental sensors in a numerical list:
/usr/lpp/diagnostics/bin/uesensor -a

3 0 11 87 P1
9001 0 11 2345 F1
9004 0 11 2 V1
9004 1 9 2 V2

Return the status of sensor 9004, index 1:
/usr/lpp/diagnostics/bin/uesensor -t 9004 -i 1
9

Return the value of sensor 9004, index 1:
/usr/lpp/diagnostics/bin/uesensor -t 9004 -i 1 -v
2



[실제 시스템 예제 - 6F1]
# /usr/lpp/diagnostics/bin/uesensor -l
  Sensor = thermal sensor
  Status = Normal
  Value = 21 Degrees Celsius
  Physical Location Code = L1



#/usr/lpp/diagnostics/bin/uesensor -a
3 0 11 21 L1





----------------------------------------

AIX temperature sensors

----------------------------------------

By executing the command /usr/lpp/diagnostics/bin/uesensor, you can, on supported platform, get the fan speeds and temperature of your system:


[root@sys /] /usr/lpp/diagnostics/bin/uesensor -a 3 0 11 31 P1 9001 0 11 2100 F1 9001 1 11 2760 F2 9001 2 11 1890 F3 9001 3 11 1890 F4 9002 0 11 5129 P1 9002 1 11 3129 P1 9002 2 11 5129 P1 9002 3 11 12077 P1 9004 0 11 3 P3-V1 9004 1 11 3 P3-V2 9004 2 11 3 P3-V3
diag 메뉴를 통해서 접근하는 방법----------------------------
diag-->Task Selection-->Display Sysem Environmental Sensors
(참고) p670과 p690은 지원안되네요..ㅠㅠ
한국 IBM UNIX 기술영업부, TSG 에서 작성하였습니다. -------------------------------------------------- 시스템의 온도는 Service Processor 를 통해 monitoring 됩니다. 모든 pSeries 서버가 이를 지원하는 것은 아닙니다. bootinfo -p 명령어를 수행했을 때 chrp 로 나오는 CHRP(Common H/W Reference Platform) 서버기종에서 주로 사용가능합니다. 서버의 Firmware 가 제공하는 값을 보여주는 것이기 때문에 CHRP 모든 기종에서 지원되지는 않습니다.
수치적으로 온도를 확인할 수 있는 서버인지를 점검하는 명령어는 다음과 같습니다. # /usr/lib/boot/bin/dmpdt_chrp | grep ibm,environmental | grep sensor
결과값이 없으면 온도를 확인할 수 없는 서버이고 결과값이 있으면 온도확인이 가능한 서버입니다. p690, p670 에서는 System Firmware Level 에서의 기능차이로 인해 온도확인이 불가능합니다.
그러나 수치적으로 온도를 확인할 수 없는 서버일지라도 시스템에 문제를 일으킬 수 있는 온도를 넘게 되면 Error Message 가 시스템상에 보고되어 errpt 를 통해 확인이 가능하므로 이로 인한 장애를 예방할 수 있게 됩니다.
번호 제목 글쓴이 날짜 조회 수
공지 [공지] 게시자료 열람자유. 불펌금지입니다. 조인상 2010.12.07 109064
131 일명 '돼지코' 전원탭과 탭코드를 연결하는 법 조인상 2010.05.11 20846
130 number of process 개수 조정법 조인상 2010.05.11 20631
129 P5 전면 Display 패널에 관하여 [1] file 조인상 2010.05.11 20625
128 Installation and Initial Configuration of the CDE 조인상 2010.05.11 20601
127 Power7, HACMP, Oracle RAC, WAS, PowerVM, VIO [9] 조인상 2010.11.17 20563
126 GPFS ver.3 Manual [1] 조인상 2011.12.01 20524
125 mksysb 백업중 부팅불가할지도모른다는 메시지 나올경우. 조인상 2010.05.11 20519
124 java heap memory 관련에러 조인상 2010.05.11 20507
123 [AIX] NFS service 조인상 2010.05.11 20476
122 케이블 라벨링 탭 file 조인상 2010.05.11 20457
121 CDE 설치 및 초기구성 [1] file 조인상 2010.05.11 20425
120 네트웍 관련 (IP 세팅, 라우팅 세팅, 속도 세팅) [1] 조인상 2010.05.11 20251
119 네트웍카드 NIC 에서 en ent et 의 차이점 file 조인상 2010.05.11 20178
118 IBM Integrated Virtualization Manager White Book (IVM 백서) file 조인상 2012.01.03 20138
117 telnet 관련사항.... 조인상 2010.05.11 19932
116 AIX에서_JDK(JAVA)_다운로드_및_설치방법 [1] file 조인상 2010.05.11 19810
115 메뉴얼 링크 [1] 조인상 2010.05.11 19627
114 32KB 이상 파일 복사시 out of memory 에러 발생에 대한 복구(indirect segment 문제) 조인상 2010.06.10 19543
113 AIX 에서 Hot-Plug 방식으로 카드 추가하기 file 조인상 2011.08.01 19438
112 p5 서버 System Attention Indicator LED 끄기 조인상 2010.05.11 19381
서버에 요청 중입니다. 잠시만 기다려 주십시오...